Basic Info.
Model NO.
icu patient monitor
Classification
Imaging Diagnostic Equipment
Certification
CE, ISO13485
Electrical Value Detection Range
0-350bpm
ECG Amplification Width
0.05Hz-100 Hz
S-T Segment Monitoring
-2.0mv~2.0mv
Electrode off Indication
Sound, Light Prompt
Standard Configuration
Adult Electrocardiogram Cable
Optional Configuration
Special ECG Cable for Children and Newborns
Alarm
Alarm Value Upper Limit, Lower Limit Can Be Set
Trademark
Sugama, Zhuohe, WLD
Transport Package
900n 2PCS/45*38*43cm, 11.5kg
Specification
44.2*37*24cm
Origin
Yangzhou, Jiangsu, China (Mainland)
Product Description
Clinical application of the patient monitor: during operation, after operation, trauma care, coronary heart disease, critically ill patients, newborns, premature infants, hyperbaric oxygen chamber, delivery room, etc.
The BEDSIDE MONITOR IS AN INSTRUMENT SET AT THE bedside and connected with the patient, which can continuously monitor various physiological parameters or some states of the patient, give an alarm or record, and it can also work as a whole with the central monitor. Product Features:
1. 12.1" color TFT display, high resolution: 800x600dpi;
2. Separated para module: ECG, NIBP, SpO2 module;
3. Real time S-T segment analysis, and ARR analysis;
4. SpO2 Pitch Tone Variation and Drug Dose Calculation;
5. Parameter waveform and characters color selectable
6. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic 7-lead ECG waveforms
7. Standby mode for Energy saving and suspend monitoring;
8. Capture dynamic waveforms;
9. Internal storage: 3600s full-disclosure waveform review;
10. External storage: SD card slot enables memory extension;
11. Built-in rechargeable lithium battery, and battery volume checking,
12. VGA Output; AC power checking
13. Efficient resistance to interference of defibrillator and HF knife;
14. High accuracy SpO2 &NIBP, workable for neonate;
15. Networking capacity and TCP/IP networking platform enable abundant future upgrade
16. Time delay switch-off function keep the monitor data restart monitor;
17. Complete and flexible mounting solution for transportation and in-patient monitoring
Standard Parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.
Optional Parameter: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-Sp02,Masimo SpO2,BIS, Phaisein/ Respironics EtCO2, ICG/CO, FHR, FM, TOCO,
Standard parameters:
Ecg:
Lead selection: five lead standard; Up to 7 leads can be displayed in the same screen I, II, III, AVR, AVL, AVF, V chest lead ECG detection range: 0-350BPM
Resolution: 1bpm Accuracy: ±1%
Ecg amplification width: 0.05HZ-100 Hz S-T segment monitoring: -2.0mV to 2.0mV arrhythmia analysis: yes
Electrode off indication: sound, light prompt
Scanning speed: 6.25, 12.5, 25, 50mm/ SEC Gain selection: ×1/2, ×1, ×2, ×4
Ecg calibration: 1mV+5%
Protection and isolation withstand 4000V/AC/50Hz voltage; Ecg cable guide connection:
Standard configuration: adult electrocardiogram cable
Optional configuration: special ECG cable for children and newborns
Alarm: alarm value, lower limit can be set, automatic memory; There is alarm review;
Blood oxygen saturation:
Display: Blood oxygen number, pulse chart, waveform, pulse value Blood oxygen range: 0%-100% Adult/child/newborn resolution: 1%
Accuracy: ±2% (not defined below 70%) Pulse rate:
Measurement range: 0 ~ 2501bpm Pulse accuracy: ±1bpm
Alarm range: upper limit 80 ~ 2501bpm
The lower limit is 20 ~ 1501BPM
Sensors:
Standard configuration: Adult soft ring
Optional configuration: children's soft hand ring, newborn bundle alarm value: upper and lower limits can be set, automatic memory
Non-invasive blood pressure:
Measurement method: intelligent oscillation method
Measurement parameters: systolic blood pressure, diastolic blood pressure, mean blood pressure, pulse rate Working mode: manual, automatic, continuous measurement
Unit: mmHg/kPa Optional
Automatic measurement interval: 0 to 250min adjustable overvoltage protection: software and hardware overvoltage protection
Measurement range: adult: 10mmHg ~ 300mmHg Children: 10mmHg ~ 200mmHg neonates 10mmHg ~ 155mmHg
Cuff pressure range: 0-320 mmHg
Cuff:
Standard configuration: Adult cuff
Select configuration: newborn cuff, child cuff cuff inflation time: less than 6 seconds
Test venting time: less than 15 seconds Alarm range:
Upper systolic blood pressure is 120-240 MMHG
The lower limit of 40-150 mmHg
The upper limit of average pressure is 70-200 mmHg
The lower limit of 20-120 mmHg
The upper limit of diastolic blood pressure is 50-80 mmHg
The lower limit of 10-80 mmHg
Temperature:
Temperature range: 0 ° C to 50 ° C Temperature measurement error: ±0.1 ° C
Resolution: 0.1ºC Accuracy: ±0.1 ºC Probe:
Standard configuration: permanent body temperature probe
Optional configuration: esophageal temperature probe, rectal temperature probe. Alarm value: upper and lower limits can be set, automatic memory
Alarm: IT CAN SET alarm for all monitoring parameters, and has alarm device that sends out sound and light, and can cancel alarm
Breathing:
Measurement method: chest impedance method
Respiratory rate (RR) : A. Measurement range: 0-120bpm
B. Measurement accuracy: ± 1BPM or 5%bp
Alarm: Alarm value can be set, automatic memory
Address:
No. 138, Xishan South Road, Chenji Town, Yizheng City, Yangzhou, Jiangsu, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Health & Medicine
Management System Certification:
ISO 13485
Company Introduction:
WLD is a professional supplier of medical product development, covering thousands of products in the medical field. We have our own factory that specialized in manufacturing gauze, cotton, non woven products, all kinds of plasters, bandages, tapes, syringe and the other medical products. We have gotten CE and ISO13485.
Based on our principles of honesty and joint venture with our customers, our company has been constantly expanding to take a leading position in the medical industry, our high efficient team had developed new products every year, thus maintaining the fast growth trend of the company, in order to enhance our management level, as well as to ensure that such high leavel products in the medical industry to meet international quality requirements.
Our company offers variety of products which can meet your multifarious demands. We adhere to the management principles of "quality first, customer first and credit-based" since the establishment of the company and always do our best to satisfy potential needs of our customers. Our company is sincerely willing to cooperate with enterprises from all over the world in order to realize a win-win situation since the trend of economic globalization has developed with anirresistible force.