Basic Info.
- Model NO.
- Normal bedside patient monitor
- Certification
- CE, ISO13485
- Group
- Female or Male
- Electrical Value Detection Range
- 0-350bpm
- Resolution
- 1bpm
- Accuracy
- ±1%
- ECG Amplification Width
- 0.05Hz-100 Hz
- S-T Segment Monitoring
- -2.0mv~2.0mv
- Arrhythmia Analysis
- Yes
- Electrode off Indication
- Sound, Light Prompt
- Standard Configuration
- Adult Electrocardiogram Cable
- Optional Configuration
- Special ECG Cable for Children and Newborns
- Alarm
- Alarm Value Upper Limit, Lower Limit Can Be Set
- Transport Package
- 900n 2PCS/45*38*43cm, 11.5kg
- Specification
- 44.2*37*24cm
- Trademark
- Sugama, Zhuohe, WLD
- Origin
- Yangzhou, Jiangsu, China (Mainland)
- Production Capacity
- 2000pieces/Month
Product Description
Clinical application of the patient monitor: during operation, after operation, trauma care, coronary heart disease, critically ill patients, newborns, premature infants, hyperbaric oxygen chamber, delivery room, etc.
The BEDSIDE MONITOR IS AN INSTRUMENT SET AT THE bedside and connected with the patient, which can continuously monitor various physiological parameters or some states of the patient, give an alarm or record, and it can also work as a whole with the central monitor.
Product Features:
Feature
1-12.1" TFT color LCD, 800*600dpi
2-Standard 5 para: ECG, SpO2, NİBP, TEMP, RESP
3-Fanless design, quiet, energy-saving and clean.
4-With standard interface, OxyCRG, trend chard, big character interface and view bed,
5-Operation mode: keys and buttons.
6-Display up to 8-channel waveform on one screen.
7-NIBP measurement mode: Manual/AUTO/Continuous, storage for 1000-group NIBP data.
8-Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
9-Drug concentration calculation and titration table functions.
10-Print trend table data with one-key.
11-Connect to Central Monitoring System WiFi or wired mode.
12-AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
13-Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).
Standard parameters:
Ecg:
Lead selection: five lead standard; Up to 7 leads can be displayed in the same screen I, II, III, AVR, AVL, AVF, V chest lead ECG detection range: 0-350BPM
Resolution: 1bpm Accuracy: ±1%
Ecg amplification width: 0.05HZ-100 Hz S-T segment monitoring: -2.0mV to 2.0mV arrhythmia analysis: yes
Electrode off indication: sound, light prompt
Scanning speed: 6.25, 12.5, 25, 50mm/ SEC Gain selection: ×1/2, ×1, ×2, ×4
Ecg calibration: 1mV+5%
Protection and isolation withstand 4000V/AC/50Hz voltage; Ecg cable guide connection:
Standard configuration: adult electrocardiogram cable
Optional configuration: special ECG cable for children and newborns
Alarm: alarm value, lower limit can be set, automatic memory; There is alarm review;
Blood oxygen saturation:
Display: Blood oxygen number, pulse chart, waveform, pulse value Blood oxygen range: 0%-100% Adult/child/newborn resolution: 1%
Accuracy: ±2% (not defined below 70%) Pulse rate:
Measurement range: 0 ~ 2501bpm Pulse accuracy: ±1bpm
Alarm range: upper limit 80 ~ 2501bpm
The lower limit is 20 ~ 1501BPM
Sensors:
Standard configuration: Adult soft ring
Optional configuration: children's soft hand ring, newborn bundle alarm value: upper and lower limits can be set, automatic memory
Non-invasive blood pressure:
Measurement method: intelligent oscillation method
Measurement parameters: systolic blood pressure, diastolic blood pressure, mean blood pressure, pulse rate Working mode: manual, automatic, continuous measurement
Unit: mmHg/kPa Optional
Automatic measurement interval: 0 to 250min adjustable overvoltage protection: software and hardware overvoltage protection
Measurement range: adult: 10mmHg ~ 300mmHg Children: 10mmHg ~ 200mmHg neonates 10mmHg ~ 155mmHg
Cuff pressure range: 0-320 mmHg
Cuff:
Standard configuration: Adult cuff
Select configuration: newborn cuff, child cuff cuff inflation time: less than 6 seconds
Test venting time: less than 15 seconds Alarm range:
Upper systolic blood pressure is 120-240 MMHG
The lower limit of 40-150 mmHg
The upper limit of average pressure is 70-200 mmHg
The lower limit of 20-120 mmHg
The upper limit of diastolic blood pressure is 50-80 mmHg
The lower limit of 10-80 mmHg
Temperature:
Temperature range: 0 ° C to 50 ° C Temperature measurement error: ±0.1 ° C
Resolution: 0.1ºC Accuracy: ±0.1 ºC Probe:
Standard configuration: permanent body temperature probe
Optional configuration: esophageal temperature probe, rectal temperature probe. Alarm value: upper and lower limits can be set, automatic memory
Alarm: IT CAN SET alarm for all monitoring parameters, and has alarm device that sends out sound and light, and can cancel alarm
Breathing:
Measurement method: chest impedance method
Respiratory rate (RR) : A. Measurement range: 0-120bpm
B. Measurement accuracy: ± 1BPM or 5%bp
Alarm: Alarm value can be set, automatic memory